Bettersizer Series

The Bettersizer Series helps you spot changes in particle size between batches sooner with automated laser diffraction measurements. Particle imaging on selected models lets you examine individual particles when a result looks unusual, so you can better understand what changed before adjusting a formulation or production process.

Use the Bettersizer S3 Plus to track ultrafine particles during formulation development and check for oversized particles in the same sample. If a batch shows an unexpected increase in coarse particles, the Bettersizer 2600 Plus with optional dynamic imaging lets you inspect them for signs of agglomeration. The Bettersizer 2600 lets you test dry powders and suspensions on the same instrument by switching between dry and wet dispersion. For routine quality control, the compact Bettersizer ST automates wet dispersion and measurement, making it easier for operators to follow the same procedure across shifts.

Laser Diffraction at a Glance

What's New in Bettersizer 2600 Plus?

Hear from our Sales Manager, Kiwan Park, in this three-minute Q&A. He explains how the Bettersizer 2600 Plus reduces hands-on work, makes the measurement cell easier to access for maintenance, and uses optional imaging to add particle shape information to your laser diffraction results.

How Laser Diffraction Measures Particle Size

1. How Particles Scatter Light

When a laser beam passes through a dispersed sample, particles scatter light at angles inversely proportional to their size: large particles scatter light at narrow angles with high intensity close to the beam axis, while fine particles scatter light across wide angles at lower intensity. 

2. Angular Detection and Optical Models

An array of photodetectors positioned across forward, side, and backscattering angles records the scattered light intensity pattern. The software then converts this angular energy spectrum into a particle size distribution using an optical model—applying Mie theory (which requires the refractive index of the particle and medium) for fine or translucent particles, or the Fraunhofer approximation for coarse, opaque particles. 

3. Volume-Based Size Distribution Results

Laser diffraction reports results as a volume-weighted particle size distribution, showing the percentage of total sample volume occupied by each size class. Key percentiles summarize the curve: for example, a D50 of 20 μm means 50% of the total sample volume consists of particles smaller than 20 μm. 

Schematic of a laser diffraction optical bench

Schematic of a laser diffraction optical bench.

4. Bettersizer Comparison Guides

Compare Our Laser Diffraction Models

Review side-by-side optical light-path designs, dispersion unit compatibility, and imaging specifications against conventional laser diffraction analyzers.

Model Bettersizer
2600 Plus
Bettersizer
S3 Plus
Bettersizer
2600
Bettersizer
ST
LD Size Range Wet 0.02–2,600 μm;
Dry 0.1–2,600 μm
0.01–3,500 μm Wet 0.02–2,600 μm;
Dry 0.1–2,600 μm
0.1–1,000 μm
Extended / Aux Capability DIA 2–3,500 μm (PIC-1);
RI
DIA 2–3,500 μm (Built-in);
RI
Refractive Index (LD only) Integrated Wet Tank
Repeatability & Accuracy ≤ 0.5% (both) ≤ 0.5% (both) ≤ 0.5% (both) ≤ 1% (both)
Dispersion & Cycle Modular Wet & Dry, ≥ 10 s Wet (Aqueous/Solvent), ≥ 10 s Modular Wet & Dry, ≥ 10 s Built-in Wet, < 1 min

FURTHER READING  / COMPARISON

Want to know which one
is best for you?

Read the comparison page to see what our instruments can help your workflow.

Read the Comparison  →

 Laser Diffraction · Bettersizer Series

Bettersizer Series