Home > Products > BT-Online2
BT-Online2 product banner

BT-Online2

The BT-Online2 applies patented Fourier and Inverse Fourier Optical System, providing reliable measurement results with the same accuracy level as that of the laboratory instrument. A total of 92 detectors are precisely arranged in the optical setup that is responsible for accurate particle size analysis ranging from 0.02 to 2000μm using the wet method. With external dilution system, the BT-Online2 can handle samples with high solid contents, greatly expanding its application areas. Up to 4 process lines can be attached to the BT-Online2, which saves your investment, improves your space efficiency, and simplifies data management.

Features and Benefits

  • Patented optical setup promotes measurement accuracy
  • Reliable pneumatic sampling system
  • Monitoring of up to 4 process lines
  • External dilution system realizes optimal obscuration
  • Same measurement accuracy as laboratory instrument
  • Filtration system enables recycling of organic solvent

Overview

BT-Online2—Innovative solution for online measurement using wet method

The BT-Online1 is used as an online particle size analyzer for dry particles within the size range of 0.1 to 1000 μm. The BT-Online1 is integrated into a process loop, providing real-time measurement results that assist in quality inspection and parameter monitoring.

 

Patented optical setup promotes measurement accuracy 

The patented Fourier and Inverse Fourier Optical System provided by Bettersize Instruments contains forward, lateral, and backward detectors, realizing the detection of scattered light signals in a very wide angular range.

Benefits of the optical setup:

  • Tilted sample cell alleviates total internal reflection. 
  • Expands measurement range
  • Improves the measurement accuracy for small particles.

 

Patented-optical-setup-promotes-measurement-accuracy

 

Reliable pneumatic sampling system 

 

This design allows:

  • Effective sample extraction without cross-contamination
  • Good operation safety without using electricity

 

Reliable-pneumatic-sampling-system

 

Achieving optimal obscuration through external dilution  

In most instances, the solid contents of the samples are quite high, resulting in high obscuration when samples are introduced to the BT-Online2. Hence, an external dilution system is necessary for primary dilution.

 

External-dilution-system-of-the-BT-Online2

 

Align with laboratory instrument 

 

Align-with-laboratory-instrument-1

By performance verification, the measured value provided by the BT-Online2 is consistent with the nominal value of the working reference standard.

 

Align-with-laboratory-instrument-1

The result deviations between the BT-Online2 and the lab instrument are quite small — the particle size curves almost overlap each other.

 

Filtration system enables recycling of organic solvent 

When organic solvent is applied as a carrier instead of water, a movable filtration system is available that works hand in glove with the BT-Online2 for recycling the organic solvent, which saves your investment.

 

Filtration-system-enables-recycling-of-organic-solvent

 

Monitoring of up to 4 process lines 

Up to 4 process lines can be attached to the BT-Online2 with individual SOPs. The measurement result for each process line is intuitively displayed in the software, which saves equipment investment and simplifies data management.

Monitoring-of-up-to-4-process-lines

 

Application    

 

Application-of-the-BT-Online2

 

  • Continous and accurate measurement in various industries 

A patented optical system offers accurate measurement results with outstanding reproducibility.

 

Continous-and-accurate-measurement-in-various-industries-of-bt-online2
Continous-and-accurate-measurement-in-various-industries-of-bt-online2

 

  • Measurement procedure of the BT-Online2 with an external dilution system

As an accessory, an external dilution system can be connected to the BT-Online2, offering a solution for measuring concentrated samples in case of multiple scattering. The external dilution system has 4 inlet ports that correspond to 4 process lines and 1 outlet port for delivering the primary diluted sample.

Measurement-procedure-of-the-BT-Online2-with-an-external-dilution-system
Measurement-procedure-of-the-BT-Online2-with-an-external-dilution-system

Measurement-procedure-of-BT-Online2

 

 

 

Curated Resources

    More resources

    • Bettersizer S3 Plus

      Bettersizer S3 Plus

      Particle Size and Shape Analyzer

      Measurement range: 0.01 - 3,500μm (Laser System)

      Measurement range: 2 - 3,500μm (Image System)

    • Bettersizer 2600

      Bettersizer 2600

      Laser Diffraction Particle Size Analyzer

      Measurement range: 0.02 - 2,600μm (Wet)

      Measurement range: 0.1 - 2,600μm (Dry)

    • Bettersizer ST

      Bettersizer ST

      One-stop Particle Size Analyzer

      Dispersion type: Wet

      Measurement range: 0.1 - 1,000µm

      Repeatability: ≤1% variation

    • BT-Online1 online particle size analyzer for dry powder

      BT-Online1

      Online Particle Size Analyzer

      Dispersion type: Dry

      Measurement range: 0.1 - 1,000μm

      Accuracy: ≤1% (D50 of certified reference material)