Know your Particles. Know Bettersize.
Key Takeaways
- Use laser diffraction for APIs and micrometer-scale particles, DLS/ELS for nanoparticles and biologics, and DIA for shape and agglomerate analysis.
- Control dispersion and optical settings for LD, sample conditions for DLS/ELS, and thresholding and sampling for DIA.
- Confirm instrument suitability with representative samples, predefined acceptance criteria, qualification support, and method validation.
Particle Size Analyzers for Pharma Labs
| Comparison Point | LD | DLS / ELS | DIA |
|---|---|---|---|
| Best suited to | APIs, excipients, and micro-scale suspensions | Colloidal nanoparticles, nanomedicines and biologics screening | Particle shape, agglomerates and oversized particles |
| Result represents | Equivalent spherical size | Hydrodynamic size; zeta potential | Projected particle size and shape |
| Typical outputs | Volume-based PSD, D10, D50, D90 and span | Z-average size, PDI and zeta potential | Image-based size distributions, shape parameters and particle images |
| Critical controls | Dispersion, obscuration, optical properties and model selection | Concentration, viscosity, temperature and sample handling | Dispersion, thresholding and sampling statistics |
| Primary strength | Fast ensemble particle sizing | Sensitive detection of nanoscale and colloidal change | Direct visual evidence |
| Important limitation | Results for fibrous or plate-like particles require careful interpretation | Larger scatterers can dominate the result | Counts captured particles, not every particle in the original sample |
| Platform | Measurement Approach | Sample-handling configuration |
|---|---|---|
| Bettersizer 2600 Plus | LD with optional PIC-1 DIA | Interchangeable wet and dry dispersion units, including corrosion-resistant wet options |
| Bettersizer S3 Plus | Wet LD with integrated DIA | Integrated wet-dispersion workflow; optional 60-sample BT-A60 autosampler |
| Mastersizer 3000+ | LD with an optional dynamic imaging accessory | Wet/dry configuration depends on selected accessories |
| Litesizer DIF 500 | LD with optional wet DIA | Interchangeable wet and dry dispersion units |
| Partica LA-1000 series | LD with integrated DIA | Wet and dry dispersion units |
| Microtrac SYNC | Simultaneous LD and DIA | Wet recirculation or compressed-air dry dispersion through interchangeable modules |
| Platform | Measurement Approach | Distinctive Capabilities |
|---|---|---|
| BeNano Series | DLS / PALS-ELS / SLS | Low-volume measurement, adjustable scattering volume for concentrated samples, programmable temperature workflows, and integrated concentration detection |
| Zetasizer series | DLS / M3-PALS ELS/SLS | Multi-angle DLS, low-volume cells and optional sample automation |
| Litesizer DLS 701 | DLS / cmPALS ELS / SLS | Automatic angle selection, transmittance monitoring and optical filtering options |
| Platform | Measurement Approach | Distinctive Capabilities |
|---|---|---|
| BeVision D3 Series | Dual-camera DIA; wet and dry dispersion | Automated analysis of powders and granules, with particle-level images, size and shape descriptors, oversize/undersize screening and sieve-correlation output |
| CAMSIZER X2+ | Dual-camera DIA; wet and dry dispersion | Modular dry and wet workflows, simultaneous coverage of fine and coarse particles |
| Litesizer DIA 500 | Multi-magnification DIA; wet and dry dispersion | Interchangeable dispersion modes, automatic objective switching, merged size ranges |
| Evaluation area | Question for every supplier | Evidence to request |
|---|---|---|
| Sample preparation | Which dispersants, solvents, pressures and cleaning steps fit the sample? | Representative sample test and draft method conditions |
| Method robustness | Which settings and acceptance criteria should be controlled in the SOP? | Repeatability study and method-development record |
| Data integrity and 21 CFR Part 11 | Which user, audit-trail, method-control and review functions are included? | Exact software configuration, Part 11 function matrix and data-flow review |
| Qualification | What IQ/OQ/PQ, training and reference-material support is available? | Protocols, scope of work and regional service deliverables |
| Method validation | What remains the laboratory's responsibility after qualification? | Validation plan linked to intended use and risk |
| Lifecycle support | What are the accessory, consumable, maintenance and method-transfer needs? | Comparable multi-year service and support plan |
| Laboratory profile | Primary configuration | Complementary method | Why it fits |
|---|---|---|---|
| API and excipient R&D or QC | Bettersizer 2600 Plus | Dynamic Image Module PIC-1 when particle shape or coarse material is recurring | Wet and dry LD workflows for powders and suspensions, |
| Support: SOP-based workflows, IQ/OQ documentation, 3-year warranty | |||
| Standards: ISO 13320, ISO 13322-2, USP <429>, Ph. Eur. 2.9.31 , 21 CFR Part 11 support | |||
| Powder laboratory needs routine particle-shape evidence | Bettersizer S3 Plus | Dedicated DIA only when an independent imaging workflow is required | Integrated wet LD and DIA for ensemble PSD, particle images and shape measurement, with an optional 60-sample BT-A60 autosampler. |
| Support: SOP-based workflows, IQ/OQ documentation, 3-year warranty | |||
| Standards: ISO 13320, ISO 13322-2, USP <429>, Ph. Eur. 2.9.31 , 21 CFR Part 11 support | |||
| Nanomedicine and formulation laboratory | BeNano 180 Zeta Max | LD when a micrometer-scale tail matters | DLS/ELS/SLS for size, zeta potential and molecular weight. |
| Support: SOP-based workflows, IQ/OQ documentation, 3-year warranty | |||
| Standards: ISO 22412, ISO 13099, 21 CFR Part 11 support | |||
| Biologics screening laboratory | BeNano 180 Zeta Max | Orthogonal methods for separation, identification or counting | Low-volume DLS and temperature-controlled screening |
| Support: SOP-based workflows, IQ/OQ documentation, 3-year warranty | |||
| Standards: ISO 22412, ISO 13099, 21 CFR Part 11 support | |||
| Particle-shape and root-cause laboratory | BeVision D3 | LD for a statistically robust ensemble PSD | DIA for particle-level images, size/shape descriptors and oversize/undersize investigation. |
| Support: SOP-based workflows, IQ/OQ documentation, 3-year warranty | |||
| Standards: ISO 22412, ISO 13099, |
Compare and Learn More
Don't just compare instruments. Find your better fit.
Contact Now →Discover Expert Insights for Smarter Particle Characterization Decisions
Learn More →Turn particle data into better decisions.
Explore the Technology →Bettersize: Global Expertise, Local Reliability.

Free Sample Testing
Send us your samples and receive professional testing using the most suitable Bettersize instrument.

Free Test Report Reading
Our application specialists will help you understand your test results and key measurement data.

Free online Demos
Join a personalized live demo to explore instrument operation, software features, and application performance.

30+ Years of Expertise
Trusted across 24,000+ installations worldwide, with responsive 24/7 technical support.

3-year Warranty
Reliable warranty coverage for long-term confidence and peace of mind.

4–6 Week Delivery Time
Efficient production and fulfillment to keep your project on schedule.
Bettersize isn't just an alternative;
we are a global standard for organizations that value both high-precision data and operational sanity.
We've built our reputation on reliability, so you can focus on yours.